Special pvc elevator cable,flat cable

Cold resistant Oil resistant high flexible cable for elevator ,crane cable

Technical data

flat cable adapted to DIN VDE 0250 part 809

Temperature range

flexing -25°C to +180°C

fixed installation -40°C to +180°C

Nominal voltage U0/U 300/500 V

Test voltage 3000 V

Minimum bending radius

10x cable thickness

Radiation resistance

up to 50x106 CJ/kg (up to 50 Mrad)

Cable structure

Bare or tinned copper, stranded to DIN VDE 0295, BS 6360 cl. 5 and IEC 60228, fine or extra fine wire stranded according to different cross-sections

1 to 25 mm² - class 6, col. 4

35 to 95 mm² - class 5

Special rubber core insulation GI1, to DIN VDE 0207 part 20

Core identification up to 5 cores, color code to DIN VDE 0293

7 cores and above with number printing

Cores laying parallel

Art.No. 28007 and 28013 cable structure 6x4

Green-yellow earth core

Special rubber outer sheath 5GM2, to DIN VDE 0207 part 21

color black

Properties

Special rubber outer sheath, cold-resistant

Extensively oil resistant, oil-/ chemical Resistance - see table Technical Informations

Extremely small bending radius

High flexibility

Minimum waste of space

Packeting possibility

Behaviour in fire:

Test according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)

Application

silicn rubber type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.

These cables are also available for export with UL-approval on request.

Installation notes

Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this purpose, the corresponding fitting instructions should be followed.

Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface of two cable trollys must be wider than the double thickness of a cable-packet.

During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively so that the biggest cross-section is laying on the top.

Further, be careful of a symmetrical load distribution.

In case of multicore flat cables with small cross-section, smaller than 2,5 mm², is very critical due to its low tensile stress. In such case, you should add 10% reserve wire for calculation.

CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EG.

Note

G = with green-yellow earth core;

x = without green-yellow earth core (OZ).

AWG sizes are approximate equivalent values. The actual cross-section is in mm².

elevator cable specifiction

Sample Show

Company Information

Our Test Equipment



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Shanghai Kuanmin Electric Co., Ltd.
Phone Number:
  86-21-60528967
Fax Number:
 86-21-51567130