2MB Memory LCD Intelligent Multiple Functions Harmonic Meter, Power Quality Analyzer with Certificates CE, ISO9001, CQC

Location:
Liling, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

Power Quality Analyzer, Harmonic Meter

Product Description

1. Product Feature

The product LCD 3 phase Intelligent Multifunction Harmonic Wave Meter is adopted industrial-grade

microprocessor as the core, adopted modern digital signal processing technology, integrated functions of

electricity quantity telesignalling, telemetry, remote control and transmitter, etc into one. It is designed directly

against primary return circuit, can accomplish monitoring function of primary return circuit. It is widely used in

industry, commerce, civilian power system and substations.

The product is equipped with high-definition, large-screen, dot LCD system, which can simultaneously display

data, characters and recorded wave graphics. The man-machine interface is more simple and better to

understand.Groups parameters such as Voltage, current, power, frequency, electric energy, harmonics, switch

status,etc. can be displayed in real-time on the panel. Set parameter includes setting system parameters,

communication parameters and analog parameters, etc. All these can be set through the panel. Data are stored in nonvolatile memory and would not be lost even on power-off. And the data may be reserved more than 10 years. With highly reliable industry standard design, adopted varieties of isolation and anti-jamming

measures, the meter can reliably run in high interference power system environments.

2. Function Profile

the Basic Measure Parameters

3. Application Area

The multifunction power meter can be used as electricity parameters indicator to replace analog pointer meter

and digital panel meter. Also it may be as the front-end collection components of automation system. And also

it may be acted as continuous measurement and monitoring unit of power distribution system. The main application

fields are following:

Factory dynamic system automation and load control; SCADA, DCS, EMS integration manufacturer; Substation general automation; Power plant Electric DAS; Post Office Power Supply Systems, Intelligent Building Energy Management System

4. Rated Parameter

a) Working Power supply

DC: Rated 220V, Voltage permissible variation: -20% ~ +20%AC: Rated 220V, Voltage permissible variation : -20% ~ +20%

b) AC Input

Phase voltage: Rated 57.7V, 220V or 400VPhase current: Rated 5A or 1A

c) Analog Output(AO)

Rated 20mA, output range 4-20mA (1.2 times overload)Load capacity 500Ω

d) DI

24V DC excitation & self-excitationFront debounce time: 20ms

e) Relay Output

Electromagnetic relayContactor capacity: 5A, AC250V

f) Communication Interface

Interface Type: RS-485, 2-wire typeOperation Mode: Half-duplex mode Communication speed: 1200, 2400, 4800, 9600

Communication protocol: MODBUS

5. Frame and Install Size

96 Square (Frame Size: 96*96*96mm Install Size: 91.00*91.00mm, Optional Install Size:88*88mm)

42 Square (Frame Size: 120*120*96mm Install Size:111.00*111.00mm, Optional Install Size:108.*108mm)

6. Terminals Wiring

7. Typical Terminal Diagram

8. Harmonic data register

Packaging & Shipping

Package: 42*23.5*34 CM, 40pcs/CTN. Outline dimension: 96*96*90 mm

Our Services

Provide customized service.

About sample, we may ship out the goods within 7 working days after we conform the goods payment.

Company Information

Sanda Electronic is a professional manufacturer for instrument with 14 years experiences.

Sanda products have gotten certificates such as ISO, CE and passed the test of KETOP Lab. All the products

from our company are guaranteed of their quality.

FAQ

9. Analyse and settle for device faults

Q1: No Display

A1.1 Check whether the supply power and other wiring is correctly connected and the power voltage is in the

permitted range.

A1.2 Turn off the device, then re-turn on it.

Q2 Not working properly on charged

A2.1 It may that the power voltage is not in the permitted range

A2.2 Shut off the device, then re-turn on it.

Q3 The Reading value of voltage or current is incorrect.

A3.1 Check whether the wiring model is accord with the actual wiring.

A3.2 Check whether the ratio of PT & CT is set correctly.

A3.3 Check whether GND is correct landing.

A3.4 Check whether the shield is landing.

A3.5 Check whether the PT and CT is in good condition.

Skype: helen.fu16

86-135 7422 5807

Zhuzhou Sanda Electronic Manufacturing Co.,Ltd

Official Website:http://www.zzsanda.en.alibaba.com

http://www.sanda-smartpower.com

http://www.digitalmeter-suppliers.com

Address: No.502, Wulidun Economic Development, Liling, Zhuzhou City, Hunan Province, China.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Zhuzhou Sanda Electronic Manufacturing Co., Ltd.
Phone Number:
  0086-731-2316 1000
Fax Number:
 0086-731-2366 3288