meanwell PB-1000-48 car battery charger 48v

Location:
Hangzhou, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

1000W Intelligent Single Output Battery Charger PB-1000 series

Features:

Controlled by microprocessor

2/3/8 stage charging selectable on output panel (Note 4)

Universal AC input / Full range

Built-in active PFC function, PF larger than 0.95

Protections: Short circuit / Overload / Over voltage / Over temperature

Charger for lead-acid batteries

3 color LED loading indicator

Built-in remote ON-OFF control

2-Bank charger

Temperature compensation function

FAN on/off control (depend on charging current)

3 years warranty

SPECIFICATION

MODEL

PB-1000-48

OUTPUT

BOOST CHARGE VOLTAGE

57.6V

FLOAT CHARGE VOLTAGE

55.2V

OUTPUT CURRENT

17.4A

RECOMMENDED BATTERY

CAPACITY(AMP HOURS) Note 3

60 ~ 175Ah

BATTERY TYPE

Open & Sealed Lead Acid

LEAKAGE CURRENT FROM BATTERY (Typ.)

<1mA

INPUT

VOLTAGE RANGE

90 ~ 264VAC 127 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

0.95/230VAC 0.98/115VAC at full load

EFFICIENCY (Typ.)

89%

AC CURRENT (Typ.)

1 2A/115VAC 5.2A/230VAC

INRUSH CURRENT(Typ.)

25A/115VAC 50A/230VAC

LEAKAGE CURRENT

<3.5mA / 240VAC

PROTECTION

OVER VOLTAGE

64.5 ~ 69.5V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

80°C±5°C (12V), 85°C±5°C (24V,48V) (TSW1: detect on heatsink of power transistor)

85°C±5°C (12V), 75°C±5°C (24V,48V) (TSW2 : detect on heatsink of o/p diode)

Protection type : Shut down o/p voltage, recovers automat ically after temperature goes down

SHORT CIRCUIT

YES, protected by internal circuit

REVERSE POLARITY

YES, protected by internal circuit

FUNCTION

REMOTE CONTROL

Open: Normal work Short: Stop Charging

BATTER BANKS

2 banks (A & B)

FAST CHARGE

2 / 3 / 8 stage selectable

CHARGING OK

Relay contact rating(max.): 30V/1A resistive ; "Short" when the unit is working properly, "Open"when the unit is failure or the protect ion function is activating

OUTPUT OK

Relay contact rating(max.): 30V/1A resistive ; "Short" when the battery is full, "Open" when the battery is still charging

TEMPERATURE COMPENSATION

By NTC, compensate both banks at the same time

ENVIRONMENT

WORKING TEMP.

-20 ~ +60°C (Refer to derating curve)

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C , 10 ~ 95% RH

TEMP. COEFFICIENT

±0.05%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 2)

SAFETY STANDARDS

UL60950-1, TUV EN60950-1 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I /P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55022 (CISPR22), EN61000-3-2 ,-3

EMC IMMUNITY

Compliance to EN61 000-4-2,3,4,5,6,8,11, EN55024; light industry level, criteria A

OTHERS

MTBF

127.4K hr s min. MIL-HDBK-217F (25°C )

DIMENSION

300*184*70mm(L*W*H)

PACKING

3.5Kg; 4p cs/15Kg/1 .83CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

3. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.

4. Please choose the “3 stage” selection when the charger is used to charge the batteries and power the loads in the same time.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Hangzhou Coolceen Technology Co., Ltd.
Phone Number:
  86-571-85179015
Fax Number:
 86-571-85179015