interlligent UPS off-line HB series 300VA to 1KVA JYB-1000

Location:
Shengzhen, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

Main Features of UPS off-line JYB-1000

AVR function.
High reliability with CPU control.
Advanced PWM technology for inverter output.
Advanced battery management system with automatic re-charging function.
Special surge suppression output sockets.
Perfect automatic protection against extremely high and low voltage, overload, over-current, short circuit, or low battery.

Products Description of UPS off-line JYB-1000

1, Concise, compact, easy machine appearance
2, Ultra wide input range
3, The remarkable microprocessor to ensure reliable operation
4, Automatically adjust the mains step-up, step-down to stable voltage output
5, Restart function with sine wave
6, Charging in Shutdown mode
7, For the personal computer, POS machine, ensure the machine and other miniature terminal equipment to provide reliable power protection

Products Specification of UPS off-line JYB-1000

Model

JYB-1000

Standard

1000VA/600W

Input

Voltage

220VAC

Voltage range

140-290VAC

Frequency

50Hz

Output

Voltage range(Battery Mode)

±10%

Frequency range(Battery Mode)

50Hz±1%

Transfer time

2-6ms,not more than10ms

Wave type(Battery)

Simulated sine-wave

Battery

Battery Model and Qty.

12V7AH*2

Charging time

To 90% in 4 hours

Indicator light

Utility Power

Green light

Battery Power

Yellow light flashes, red light

Physical performance

Size (mm) L*W*H

350*146*160

Weight (Kg)

8.9

Warming sound

Battery mode

Sound every 10 min.

Low power

Sound every min.

Overload

Sound every 0.5 min.

Error

Continuous sound

Protection function

Whole protection

Overload, over charge and deep discharge

Use environment

Temperature

0-90% humidity & 0-40ºC

Noise

< 40dB

Using Tips of UPS off-line

1, Use environment must be good, ventilation should be good for heat dissipation, and keep the environment clean.
2, Do not drive inductive load, such as currency count machine, fluorescent lamp, air conditioning, etc., so as to avoid damage.
3, Output load control around 60% is the best, with the highest reliability.
4, UPS load is too low (such as 1000VA UPS with 100VA load) to may cause the deep discharge of the battery, can reduce the service life of the battery, should avoid it as far as possible.
5, Proper discharge can help with battery activation, shut down the Utility power every three months to discharge UPS with load, so that we can extend the service life of the battery.
6, For most small UPS, open it at work and avoid load startup, closed when after work; For UPS network computer room, because most of the network is working 24 hours a day, so the UPS also must be all-weather running.
7, UPS should charge in time after discharge, avoid damage due to excessive self-discharge battery.



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 Shenzhen Comemoon Electronics Co., Ltd.
Phone Number:
  86-022-3216548
Fax Number: