LC1-D Contactor

Location:
Yueqing, China ( Mainland)
Status:
New
Sample Availibility:
yes
Payment Terms:
Cash, Bank Transfer, Letter of Credit, T/T, L/C

Product Description

-China Top 500 Enterprise

-26 years rich experience in manufacturing electrical products

-Sales in over 100 countries

LC1-D Contactor

Application
CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to 95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4, GB14048-4.

Standard control voltage

Voltage50Hz60Hz50/60Hz
24B5B6B7
42D5D6D7
48E5E6E7
110F5F6F7
220M5M6M7
230P5-P7
240U5U6U7
380Q5Q6Q7
400V5-V7
415N5-N7
440R5R6R7
500S5--
660Y5--

Specification

TypeCJX2-09 (LC1-D09)CJX2-12 (LC1-D12)CJX2-18 (LC1-D18)CJX2-25 (LC1-D25)CJX2-32 (LC1-D32)CJX2-40 (LC1-D40)CJX2-50 (LC1-D50)CJX2-65 (LC1-D65)CJX2-80 (LC1-D80)CJX2-95 (LC1-D95)
Rated working current (A)AC39121825324050658095
AC43.557.78.51218.524283744
AC3 capacity of three-phase squirrel-cage motor AC3(kW)220/230V2.2345.57.5111518.52225
380/400V45.57.5111518.522303745
415V45.5911152225374545
440V45.5911152230374545
500V5.57.5101518.52230375555
660/690V5.57.5101518.53033374545
Rated heat current (A)2020324050608080125125
Electrical lifeAC4X1042020-1520-715-715-710-777-67-57-5
AC3X10622222221.61.61.6
Mechanical lifeX10620202020202050201010
Number of the contact3P+NO
3P+NC
Matched auxiliary contact typeLA1-DN02(2NC),LA1-DN11(1NO+NC),LA1-DN20(2NO),LA1-DN22(2NO+2NC),LA1-DN40(4NO,LA1-DN04(4NC),LA1-DN13(1NO+3NC),LA1-DN31(3NO+1NC)
Matched time delay auxiliary contact typeTime delay after power on:LA2-DT0(0.1-3S),LA2-DT2(0.1-30S),LA2-DT4(10-180S),Time delay after power off:LA3-DR0(0.1-3S),LA3-DR2(0.1-30S),LA3-DR4(10-180S)

CJX2-F(LC1-F) AC Contactor

General:

CJX2-F series AC contactor is applicable in the circuit rated voltage up to 1000V AC. 50/60Hz, rated current up to 781A, for long distance breaking curcuit and frequency starting or controlling the motor. It also can be used for the control of distributing ciurcuits of rated current from 200A to 1600A(AC-1)/115A to 780A(AC-3). The products cmply with IEC 60947-4.

Type

CJX2-F115

CJX2-F150

CJX2-F185

CJX2-F225

CJX2-F265

CJX2-F330

CJX2-F400

CJX2-F500

CJX2-F630

Main circuit characteristic

Poles

3P.4P

Rated operation voltage (Ue

V

380,660,1000

Rated insulation voltage (Ui

V

1000

Rated heating current (Ith)

A

200

200

275

275

315

380

450

630

800

Rated operation current (Ie)

AC-3 380V

A

115

150

185

225

265

330

400

500

630

AC-3 660V

A

86

108

118

137

170

235

303

353

462

AC-3 1000V

A

46

51

71

90

112

115

200

232

331

AC-4 380V

A

52

60

79

85

105

117

138

147

188

AC-4 660V

A

49

61

69

82

98

118

135

145

170

Max.power of 3 phase motor controlled

AC-3 220V

Kw

30

40

55

63

75

100

110

147

200

AC-3 380V

Kw

55

75

90

110

132

160

200

250

335

AC-3 660

Kw

80

100

110

129

160

220

280

335

450

Electrical life

AC-3

10000t

60

50

30

20

AC-4

10000t

1.5

1.5

0.8

0.5

Machinery life

10000t

600

600

500

500

Operation Frequency

AC-3

t/h

600

600

300

300

AC-4

t/h

150

150

150

150

Matching fuse type

RT16-160

RT16-200

RT16-250

RT16-315

RT16-400

RT16-400

RT16-500

RT16-630

RT16-800

Matching thermal relay type

LR9-F53

LR9-F73

Wiring capacity

mm²

50

50

95

95

150

185

30X5(2)

40X5(2)

50X5(2)

Coil

Control power voltage (Us)

AC

V

48,110,220,380,440,660,

Allowed control circuit voltage

Close

V

85%~110%Us

Open

V

20%~75%Us(AC)

Coil power

Close

VA

550

800

1200

1200

1250

1650

Keeping

VA

45

55

13

20

24

22

Loss power

W

12~16

18~24

12

14

18

20

Auxiliary contact

Rated heating current (Ith)

A

10

Rated operation voltage (Ue)

AC

V

380

DC

V

220

Rated control capacity

AC-15

VA

360

DC-13

W

33

Ambient temperature

-5~+40

Altitude

≤2000m

Relative humidity

The maximum temperature of 40 degrees, the air relative humidity not exceed 50%, at a

lower temperature can allow for a higher relative humidity, if humidity changes as a result

of occasional gel generated,should eliminate it.

Pollution level

3

Installation category

III

Installation position

The installation degree of the tilt and vertical plane should not exceed ±22.5°,

should be installed in place with no significant impact shaking and vibration

Install

CJX2-K(LC1-K) AC Contactor

CJX2-K series AC Contact is suitable for using in the circuits the rated voltage up to 660VAC 50HZ or 60HZ, rather current up to 12A in AC-3 using category, for making & breaking, frequently starting & controlling the AC motor. Combine with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC60947-4.

For motor control, from 6 to 12A(AC-3)
For the control of distribution circuits, up to 20A(AC-1)
Control circuit: A. C or D. C. And it is suitable for using in LC1-K/LC2-K/LP1-K/LP2-K

Standard power rating of 3-phase motors 50/60Hz in category AC-3 220V 380V 660V 230V 400V 415V 440V 500V 690VRated operating current AC-3 AC-1 up to 40C 440VRated nonconductive voltageInstantaneous auxiliary contactsReference
KWKWKWKWKWKWAAV
1.52.22.23336206901-CJX2-K0610/NZ/ZN
-1CJX2-K0601/NZ/ZN
2.2444449206901-CJX2-K0910/NZ/ZN
-1CJX2-K0901/NZ/ZN
35.55.544412206901-CJX2-K1210/NZ/ZN
-1CJX2-K1201/NZ/ZN

WHY US?

1. We Are Suppler of Three Gorges Project,China National Petroleum,Sinopec Group;

2. China Famous Export Enterprise, Our Products Sale in Over 100 Countries;

3. Our Laboratory is China Key Industrial Electrical Laboratory;

4. We have completely sales service system, ensure every detail is going smooth.

5. We have new designed products each year by our R&D Dpartment.

6. Perfect testing system ensure each product is qualified.

7. Want know more of us? Waiting for your inquiry.

...



This member's information has NOT been authenticated or verified by importexportleads.net or any third party. Only Gold Members have completed an authentication and verification procedure conducted by third-party credit agencies.

For more information on importexportleads Gold Membership, Click here

Contact Information

Company:
 CNC Electric Group Co., Ltd.
Phone Number:
  86-577-61989999
Fax Number:
 86-577-61891122